Connect the earth cable
directly to the workpiece or to the workpiece holder (welding bench,
welding grate, etc.) provided.
The welding site must lie between the two earth clamps : do not place the
two earth clamps too close to the welding site and – if possible –
position them symmetrically and equidistant to the welding site.
In this way you avoid a magnetic arc blowing action (sideways deflection
of the arc).
Note: Steel structures,
pipes, etc. may not be used as current conductor if they are not
themselves the workpiece that is to be welded.